CO Physical unit controller output
CO Physical unit controller output
CO Automatic / manual mode A/M
CO Automatic / manual mode A/M
CO Effective current value Xeff (INT)
CO Effective current value Xeff (INT)
CO Effective setpoint Weff (INT)
CO Effective setpoint Weff (INT)
CO Lower setpoint limit W0 (INT)
CO Lower setpoint limit W0 (INT)
Capacity 0% (read only)
5
CO Upper setpoint limit W100 (INT)
CO Upper setpoint limit W100 (INT)
The value of object 0x6407:01 CO Decimal digits current value / set point is determined and optimized
automatically during instrument power-up.
5
Examples:
fMeasure = 1.15 ln/min
object 0x6407:01 CO Decimal digits current value / set point = 3
object 0x7401:01 CO Effective current value Xeff = 1.15 x (10 x 10 x 10) = 1150
object 0x6407:01 CO Decimal digits current value / set point = 4
object 0x7402:01 CO Setpoint W (INT) = 22500
fSetpoint = 22500 / (10 x 10 x 10 x 10) = 2.25 ln/min
3
Integer16 value scaled with the value of object 0x6407:01
5
Integer16 value scaled with the value of object 0x6407:01
Page 22 EtherCAT interface 9.17.063