Bronkhorst EX-FLOW Mass Flow Manual de usuario

Busca en linea o descarga Manual de usuario para Hardware Bronkhorst EX-FLOW Mass Flow. Bronkhorst EX-FLOW Mass Flow User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 33
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
Instruction manual
Explosion proof
Flow Measurement and control
ATEX
Doc. no.: 9.17.028N Date: 29-10-2014
ATTENTION
Please read this instruction manual carefully before installing and operating the instrument.
Not following the guidelines could result in personal injury and/or damage to the equipment.
Related drawing.
No modifications permitted without
approval of the authorised person.
Vista de pagina 0
1 2 3 4 5 6 ... 32 33

Indice de contenidos

Pagina 1 - Instruction manual

Instruction manual Explosion proof Flow Measurement and control ATEX Doc. no.: 9.17.028N Date: 29-10-2014 ATTENTION Please read this instruction man

Pagina 2 - BRONKHORST HIGH-TECH B.V

BRONKHORST HIGH-TECH B.V. However, as the accuracy of the factor also depends on viscosity, pressure and temperature, special attention should be tak

Pagina 3 - Warranty

BRONKHORST HIGH-TECH B.V. 1.6 Control valve 1.6.1 Introduction Control valves are not designed to provide positive shut-off, although some models ha

Pagina 4

BRONKHORST HIGH-TECH B.V. 1.6.2 Kv-value calculation This calculation method can be used to determine the Kv-value of the main orifice of a control

Pagina 5 - TABLE OF CONTENTS

BRONKHORST HIGH-TECH B.V. 1.7 Ex-proof Coils 1.7.1 Introduction In our program we know two sorts of coils: (1) Style: XB = II 1 G Ex ia IIC T

Pagina 6 - Appendices

BRONKHORST HIGH-TECH B.V. 2 INSTALLATION 2.1 Receipt of equipment Check the outside packing box for damage incurred during shipment. Should the pa

Pagina 7 - 1 INTRINSIC SAFE SENSORS

BRONKHORST HIGH-TECH B.V. 2.4 Mounting The mounting position depends on the type of meter. The preferred position is horizontal and at high pressures

Pagina 8

BRONKHORST HIGH-TECH B.V. 2.7 Piping BE SURE THAT PIPING IS ABSOLUTELY CLEAN! DO NOT install small diameter piping on high flowrates, because the in

Pagina 9 - 1.5 Gas conversion factors

BRONKHORST HIGH-TECH B.V. 2.10 Supply pressure Do not apply pressure until electrical connections are made. When applying pressure to the system, tak

Pagina 10

BRONKHORST HIGH-TECH B.V. 3 OPERATION 3.1 General The Bronkhorst High-Tech B.V. Mass Flow Meters/Controllers are designed in such a way that they

Pagina 11 -

BRONKHORST HIGH-TECH B.V. 4 Cables 4.1 Introduction An average two-wire cable has a capacity of 120 pF per meter and an inductivity of 0.67 µH/m.

Pagina 12

BRONKHORST HIGH-TECH B.V.

Pagina 13 - 1.7 Ex-proof Coils

BRONKHORST HIGH-TECH B.V. 4.3 Control system with XB-coil For the XB-coil the calculation is as follows: Because the capacity and inductivity are ne

Pagina 14 - 2 INSTALLATION

BRONKHORST HIGH-TECH B.V. 4.5.2 Cable gland assembly customer side Fold the shield of the cable back over the cable (shield must be around the cable)

Pagina 15 - 2.6 Gas connections

BRONKHORST HIGH-TECH B.V. 5 MAINTENANCE 5.1 General At normal use, no routine maintenance is required to be performed on the meters or controllers.

Pagina 16 - 2.7 Piping

BRONKHORST HIGH-TECH B.V. 6 TROUBLESHOOTING 6.1 General For a correct analysis of the proper operation of a mass flow meter/controller it is recomme

Pagina 17 - 2.13 Equipment storage

BRONKHORST HIGH-TECH B.V. page 24 9.17.028

Pagina 18 - 3 OPERATION

APPENDIX 1 GAS CONVERSION TABLE Doc. no.: 9.02.071

Pagina 20 - 4.5 EMC and cables

GAS CONVERSION FACTOR Nr.: Name: Symbol Density ρng l[ / ] 0°C, 1 atm. Heat capacity* c cal cal g Kp− [ / . ]20°C, 1 atm. Conversion factor 20°C, 1 a

Pagina 21

GAS CONVERSION FACTOR Nr.: Name: Symbol Density ρng l[ / ] 0°C, 1 atm. Heat capacity* ccal calg Kp− [/. ]20°C, 1atm. Conversion factor 20°C, 1 atm. 5

Pagina 22 - 5 MAINTENANCE

APPENDIX 2 EC Declaration of Conformity EC Declaration of Conformity * * Also available on the Documentation / software

Pagina 23 - 6 TROUBLESHOOTING

BRONKHORST HIGH-TECH B.V. Even though care has been taken in the preparation and publication of the contents of this manual, we do not assume legal or

Pagina 27 - GAS CONVERSION FACTOR

APPENDIX 3 Enclosures (if applicable) Calibration certificate(s) Declaration on contamination Dimensional drawings Hook-up diagram Trans

Pagina 28

BRONKHORST HIGH-TECH B.V. Short-Form Operation Instruction Before installing your Mass Flow Meter/Controller it is important to read the attached l

Pagina 29

BRONKHORST HIGH-TECH B.V. TABLE OF CONTENTS 1 Intrinsic safe sensors 1.1 General description ...

Pagina 30

BRONKHORST HIGH-TECH B.V. 4 Cables 4.1 Introduction ...

Pagina 31

BRONKHORST HIGH-TECH B.V. 1 INTRINSIC SAFE SENSORS 1.1 General description The Bronkhorst High-Tech B.V. series mass flow meter is an accurate de

Pagina 32

BRONKHORST HIGH-TECH B.V. 1.4 Bronkhorst High-Tech B.V. flowhead The flowhead has the following type of protection: II 2 G Ex ib IIC T4 Gb II 2 G

Pagina 33

BRONKHORST HIGH-TECH B.V. 1.5 Gas conversion factors The general formula for determining the relationship between signal and mass flow is: V K c K c

Comentarios a estos manuales

Sin comentarios