Parameter
number
(DDE)
Parameter
name
Filter Value Description
2011-05-18 Page 2 of 5 FlowDDE database version V3.64
58 Calibration mode adjust Vref output by connecting it to analog in10
58 Calibration mode adjust analog out by connecting it to analog in11
58 Calibration mode adjust valveoutput by connecting it to analog in12
58 Calibration mode dmfc13
58 Calibration mode dmfc14
58 Calibration mode analog output = 0 %15
58 Calibration mode analog output = 100 %16
58 Calibration mode analog output = 50 %17
58 Calibration mode factory zero18
58 Calibration mode sensor differentiator (setpoint steps are needed!)19
58 Calibration mode automatic sensor configuration20
58 Calibration mode sensor temperature calibration21
58 Calibration mode customer zero (no control mode 9 needed)22
58 Calibration mode Error mode (result of previous cal mode)255
60 Monitor mode (filtered) setpoint0
60 Monitor mode controller error input signal / raw sensor signal1
60 Monitor mode controller output signal to valve2
60 Monitor mode sensor signal slow3
60 Monitor mode sensor signal slow filtered4
60 Monitor mode linearization output5
60 Monitor mode differentiator output6
60 Monitor mode differentiator output filtered7
60 Monitor mode normal sensor signal (Output)8
60 Monitor mode analog input signal9
60 Monitor mode power supply voltage10
60 Monitor mode mass flow in display unit (normally ln/min)11
60 Monitor mode volume flow in l/min12
60 Monitor mode temperature in °C13
60 Monitor mode pressure absolute in mbara14
60 Monitor mode time in msec/frequency in Hz.15
60 Monitor mode calibrated volume at actual sensor in ml16
60 Monitor mode delta-P pressure in mbarg17
60 Monitor mode atmospheric (barometer) pressure in mbara18
60 Monitor mode mass flow in kg/min19
61 Alarm register1 &H8000000000000000 No diagnostics available in warning register0
61 Alarm register1 &H8000000000000000 Diagnostics available in warning register1
62 Alarm register2 &H8000000000000000 No diagnostics available in error register0
62 Alarm register2 &H8000000000000000 Diagnostics available in error register1
67 ADC control register &H001000 ADC bipolar mode0
67 ADC control register &H001000 ADC unipolar mode1
67 ADC control register &H1000000 Disable zero measure threshold0
67 ADC control register &H1000000 Enable zero measure threshold1
67 ADC control register &H1C0000 ADC gain = 1x0
67 ADC control register &H1C0000 ADC gain = 2x1
67 ADC control register &H1C0000 ADC gain = 4x2
67 ADC control register &H1C0000 ADC gain = 8x3
67 ADC control register &H1C0000 ADC gain = 16x4
67 ADC control register &H1C0000 ADC gain = 32x5
67 ADC control register &H1C0000 ADC gain = 64x6
67 ADC control register &H1C0000 ADC gain = 128x7
69 <AlarmEnble> disable0
69 <AlarmEnble> enable1
70 Test mode idle; no action0
70 Test mode uProcessor1
70 Test mode IO2
70 Test mode RAM3
70 Test mode FRAM4
70 Test mode ADC5
70 Test mode DAC6
70 Test mode sensor7
70 Test mode valve drive circuit8
70 Test mode Vref9
70 Test mode FLOW-BUS10
70 Test mode calibration11
70 Test mode keyboard12
71 <ADC channel select> AD channel 11
71 <ADC channel select> AD channel 22
79 Tuning mode idle; no action0
79 Tuning mode sensor1
79 Tuning mode valve2
79 Tuning mode Fuzzy controller normal operation3
79 Tuning mode Fuzzy controller open at zero4
79 Tuning mode PID controller5
80 Valve default normally closed0
80 Valve default normally opened1
80 Valve default normally closed inverse controlled2
80 Valve default normally opened inverse controlled3
80 Valve default remain position4
86 IO status &H01 read diagnostic jumper (no diagnostics, read/write)1
86 IO status &H02 not used1
86 IO status &H04 read analog jumper (use cntrlmode, read/write)1
86 IO status &H08 read micro switch (read/write)1
86 IO status &H10 diagnostic jumper set (read only)1
86 IO status &H20 initialization jumper set (read only)1