BRONKHORST
1 GENERAL PRODUCT INFORMATION
1.1 INTRODUCTION
This manual will explain the operation of the software tool FlowTune. It has been written based on FlowTune V1.23,
but should be suited for former (and future) versions as well, although functionality may differ from what is described.
FlowTune is an offline instrument configuration software program for digital instruments of the MASSFLOW Select
series to select the fluidset, to change the full scale flow (capacity), to change the engineering units and to change or
add a fluid (gas).
FlowTune is designed for digital Bronkhorst
1)
instruments to be operated in an environment with pressure conditions
of 10 bar (a) or less and temperatures between 0 °C and 70 °C. It is not advised to use the software to configure
instruments which will be used in an environment exceeding these conditions.
1)
Bronkhorst: This includes Bronkhorst High-Tech B.V., Bronkhorst Cori-Tech B.V. and M+W Instruments GmbH.
1.2 REFERENCES TO OTHER APPLICABLE DOCUMENTS
Manuals and guides for digital instruments are modular. General instructions give information about the functioning
and installation of instruments. Operational instructions explain the use of the digital instruments features and
parameters. Fieldbus specific information explains the installation and use of the fieldbus installed on the instrument.
1.2.1 Manuals and user guides
Operation instructions digital instruments (document nr. 9.17.023)
FLOWBUS interface (document nr. 9.17.024)
ProfibusDP interface (document nr. 9.17.025)
DeviceNet interface (document nr. 9.17.026)
Modbus slave interface (document nr. 9.17.035)
EtherCAT slave interface (document nr. 9.17.063)
RS232 interface with FLOWBUS protocol (document nr. 9.17.027)
1.2.2 Technical drawings
Hookup diagram laboratorystyle MBC RS232 + analog (document nr. 9.16.062)
Hookup diagram industrial style MBCII RS232 + analog (document nr. 9.16.051)
Hookup diagram CORIFLOW RS232 + analog (document nr. 9.16.044)
Hookup diagram LIQUIFLOW L30 digital RS232 + analog (document nr. 9.16.073)
1.3 SUPPORTED INSTRUMENTS
Digital mass flow meters/controllers (best from versions V8.00, minimum V7.32)
1.4 SYSTEM REQUIREMENTS
Processor
x86 or x64 700 MHz or higher
Memory (RAM)
64 MB
Hard disk
20 MB available disk space
Display
800 x 600 or higher resolution, 256 colors or more